What is the recommended density for plating iCell Cardiomyocytes2?

In standard tissue culture plastic vessels, we recommend plating iCell® Cardiomyocytes2 156,000 cells/cm2 to form a monolayer. See the table below for the recommended number of plated cells for different culture formats.

Because the plating density for the iCell Cardiomyocyte2 is based on the number of live cells per area, you do not need to take plating efficiency into account when you are calculating your seeding density. Instead, use the viable cell count listed on the Certificate of Testing.